You need not unmount any partition operating as a raw or swap device.
3.
Use the disk management command to stop the disk rotation.
Execute the disk management command to perform the following
processes.
Stop the disk rotation. The Fault LED (amber) goes on
o
Instruct the operating system to remove the target disk.
o
# /opt/fujitsu/SVmco/bin/diskctrl -e /dev/sdc
Remove the hard disk at the location indicated by the Fault LED (amber)
that is on.
4.
Display the status by executing the disk management command, and
confirm the location with the Fault LED that is on.
# /opt/fujitsu/SVmco/bin/diskctrl -l
ioc0
0 /dev/sda
1 /dev/sdb
2 --mount
3 /dev/sdd
5.
Replace the disk.
You can confirm that the hard disk is inserted into slot 2 of ioc0 because
the Fault LED is on in that slot.
Fault LED-Off
Fault LED-Off
Fault LED-On
Fault LED-Off
SVmco User Guidel