Fujitsu PRIMEQUEST 1000 Series User Manual page 865

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

SVmco User Guide
the array. There is no problem if the array is recognized as being in the normal
state.
Also, if the error occurred after a change to the array configuration, no action is
necessary. If the error occurred during normal operation or after maintenance
work, power off the system, and confirm that the HDD is correctly connected. If
the array configuration is not recognized after startup, perform a restart so that it
can be recognized.
Severity:
Error
Action:
(R/M/T/S)
28559
SV RAID:%2 Device error (State change by user on disk from hot spare to
offline)
Meaning:
The HDD state changed from HotSpare to offline.
%2: Device name
Corrective action:
Replace the offline HDD. Perform a rebuild. For multi-dead, take corrective
action according to the multi-dead recovery procedure.
(HotSpare is not supported.)
Severity:
Error
857