SVmco User Guide
Severity:
Error
Action:
(R/M/T/S)
28501
SV RAID:%2 Adapter error (BBU temperature unstable) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
The battery temperature is unstable.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView. If a fan failure occurred, take corrective
action for the target unit.
If no fan failure occurred, recheck the environment temperature. If the error
recurs after you rechecked the environment temperature, replace the BBU.