Meaning:
The register test of the NIC failed. A hardware error occurred.
%d: (Example) 1209
%r: Numerical value (1 to 3 digits)
Corrective action:
An adapter failure may have occurred. Replace the adapter.
Severity:
Warning
Action:
(R/M/T/S)
11826
ixgbe:ethx Adapter error (failed STATUS register test) vendor-id=8086
device-id=%d revision=%r
Meaning:
The STATUS register test of the NIC failed. A hardware error occurred.
%d: (Example) 1209
%r: Numerical value (1 to 3 digits)
Corrective action:
An adapter failure may have occurred. Replace the adapter.
Severity:
SVmco User Guidel