Fujitsu PRIMEQUEST 1000 Series User Manual page 683

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

SVmco User Guide
A disk failure may have occurred. From the driver log message, define the
failure cause, to recover from the failure.
Severity:
Error
Action:
(R/M/T/S)
16010
GDS: /dev/sdx Device error (NVURM write error on disk) vendor=%v
model=%m serial-no=%ser
Meaning:
An NVURM write request sent to a disk terminated abnormally.
%v: (Example) FUJITSU
%m: (Example) MAP3367NC
%ser: (Example) 01234567
Corrective action:
A disk failure may have occurred. From the driver log message, define the
failure cause, to recover from the failure.
When you hot replace a disk duplicated by GDS, this message may be output at
the disk power-on/off time. In that case, check the GDS status. If there is no
problem with it, no action is necessary.
Severity:
Error
675

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents