SVmco User Guide
Identify the type of the target device from its host, id, and lun. Then, check the
sense key (extended sense) to determine the corrective action.
1 (Recovered Error): If it is a removable device, perform cleaning.
2 (Not Ready): If it is non-removable, replace the device.
3 (Medium Error): If it is a disk, replace the device. If it has removable media,
perform cleaning and replace the media.
4 (Hard Error): Replace the device.
5 (Illegal Request): Examine the software.
6 (Unit Attention): This is notification information from various devices. (e.g.,
reset status, RAID degradation if applicable)
7 (Data Protect): Check the Write Protect status.
8 (Blank Check): Check tape and other operations.
b (Aborted Command): Investigate problems in the SCSI bus and FC
transmission paths.
Severity:
Error
Action:
(R/M/T/S)
14138
scsi:%h:%c:%i:%l Device error (Volume overflow. CDB) vendor=%v
model=%m serial-no=%ser
Meaning:
637