Serverview Raid-Related Messages [Windows] - Fujitsu PRIMEQUEST 1000 Series User Manual

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

Error
Action:
( / /T/S)
7.2.19.ServerView RAID-related messages
[Windows]
This section lists ServerView RAID-related messages.
28500
SV RAID:%2 Adapter error (BBU temperature out of range) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
A temperature detected by the temperature sensor on the battery exceeded the
measurable range.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView. If a fan failure occurred, take corrective
action for the target unit.
If no fan failure occurred, recheck the environment temperature. If the error
recurs after you rechecked the environment temperature, replace the BBU.
SVmco User Guidel