2.
Confirm the location of the inserted hard disk by displaying the status
with the disk management command.
# /opt/fujitsu/SVmco/bin/diskctrl -l
ioc0
0 /dev/sda
1 /dev/sdb
3 /dev/sdc
4 /dev/sdd
Shortly after you insert the hard disk, the disk becomes accessible. Identify the
slot that has the inserted hard disk in the next step.
3.
Cause the Fault LED to blink by executing the location display function
of the disk management command.
# /opt/fujitsu/SVmco/bin/diskctrl -i ioc0/1
4.
Check whether the Fault LED of the slot that has the inserted hard disk
is blinking.
When the slot location is correct, confirm that "Fault LED-Identify" is
displayed for the slot by the status display function of the disk
management command.
Fault LED-Off
Fault LED-Off
Fault LED-Off
Fault LED-Off
SVmco User Guidel