Nic Addition Procedure; 5.4. Fc Card Hot Plugging - Fujitsu PRIMEQUEST 1000 Series User Manual

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

5.3.3.NIC addition procedure
Referring to
5.2 Common Hot Plugging Procedure for PCI
5.4. FC Card Hot Plugging
For FC card hot plugging (replacement), you need to especially consider other
matters in addition to the procedure described in
Common Procedure for PCI
The hot plugging of an FC card changes the WWN of the FC card if the WWN is
set on an FC switch or RAID device (ETERNUS). For details on how to set the
WWN again for a new card, see the respective device manuals.
This section describes hot plugging of an FC card combined with ETERNUS
MPD (multipath driver).
For details on the fjpciswap command, see
(fjpciswap).
Notes
SAN boot paths are not valid.
LTO library devices are not supported.
Depending on the Windows specifications, if the FC card connection
destination has a Page File or other such paging scheme, FC card hot
plugging may not be supported.
The error message "Source: SVagent, ID: 25004" may be output to the
event log during the replacement procedure. This message does not
indicate any problem.
card.
3.6 PCI Card Operation Command
SVmco User Guidel
card, add a NIC.
5.2 PCI Card Hot Plugging
178

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents