system after adding an optional card or hard disk to, or removing it from, a
server with this product mounted. In such case, check the status of the array by
using ServerView RAID Manager. If the array status is recognized as being
normal, there is no problem and you can ignore this message.
Severity:
Error
Action:
(R/M/T/S)
18558
SV RAID:%2 Adapter error (Logical drive missing after reboot) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
The logical drive could not be found at restart.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
If the error occurred after a change to the array configuration, no action is
necessary. If the error occurred during normal operation or after maintenance
work, power off the system, and confirm that the HDD is correctly connected. If
the array configuration is not recognized after startup, perform a restart so that it
can be recognized. Note that this event may occur on starting the operating
system after adding an optional card or hard disk to, or removing it from, a
server with this product mounted. In such case, check the status of the array by
using ServerView RAID Manager. If the array status is recognized as being
normal, there is no problem and you can ignore this message.