SVmco User Guide
18501
SV RAID:%2 Adapter error (BBU temperature unstable) vendor-
id=1000/1734 device-id=%d revision=%r
Meaning:
An abnormal battery temperature was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView RAID. If a fan failure occurred, take
corrective action for the target unit. For details on how to check the status in
ServerView RAID, see the ServerView Suite ServerView RAID Management
User Manual.
If no fan failure occurred, recheck the environment temperature. If the error
recurs after you rechecked the environment temperature, replace the BBU.
Severity:
Error
Action:
(R/M/T/S)
18502
SV RAID:%2 Adapter error (BBU temperature above threshold) vendor-
id=1000/1734 device-id=%d revision=%r
687