SVmco User Guidel
SV RAID:%2 Device error (Power state change failed on disk (from stopped
to active))
Meaning:
A power state change from stopped to active failed.
%2: Device name
Corrective action:
If the hard disk is faulty, replace it.
Severity:
Warning
Action:
(R/M/T/S)
28607
SV RAID:%2 Device error (Logical drive is not ready)
Meaning:
The logical drive is not in the ready state.
Corrective action:
Check the current state of the logical drive. If it is in the critical state, replace the
faulty hard disk, and perform a rebuild.
If it is in the offline state, reconfigure the array. Restore data from a backup.
Severity:
Warning
888