%2: Device name
Corrective action:
If the target logical drive is degraded, replace the HDD, and perform a rebuild. If
the target logical drive is offline, take corrective action according to the multi-
dead recovery procedure.
Severity:
Error
Action:
(R/M/T/S)
28511
SV RAID:%2 Device error (Migration failed on logical drive)
Meaning:
Logical drive capacity expansion failed.
%2: Device name
Corrective action:
Reconfigure the array. Restore data from a backup.
Severity:
Error
Action:
(R/M/T/S)
SVmco User Guidel
826