Fujitsu PRIMEQUEST 1000 Series User Manual page 126

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

SVmco User Guidel
If 30 minutes have passed since operating system startup, wait at least one minute, and
then try again.
SVmco : E 08758 this unit is occupied :%s
Meaning:
An attempt was made to add a card to a slot that already has another card mounted.
Corrective action:
Confirm the location of the slot in which to add a card. Then, execute the add operation.
SVmco : E 08759 command timeout(SNMP) :%s
Meaning:
A command time-out occurred because of a SVmco or SNMP error.
Corrective action:
Check the operation of SVmco and SNMP Service. If they have not been started,
start them.
After doing so, if the same message appears, perform recovery of the PCI card
■Recovery of the PCI
status. For details on recovery of the PCI card status, see
card
status.
After doing so, if the same message appears, contact your sales representative
or a field engineer.
Recovery of the PCI card status
If a command terminates with an error message during the PCI Hot Plug procedure, or
normal operation cannot be restored after replacement of a PCI card, use the following
procedure.
118