SV RAID:%2 Adapter error (BBU requires reconditioning; please initiate
recalibration) vendor-id=1000 device-id=%d revision=%r
Meaning:
The BBU needs reconditioning.
%2: Device name
%d: (Example) 0079
%r: Numerical value (1 to 3 digits)
Corrective action:
Perform a recalibration. If the error recurs after the recalibration, replace the
BBU.
Severity:
Warning
Action:
(R/M/T/S)
18592
SV RAID: Software error (Task for object cannot be started. The scheduler
has disabled the task)
Meaning:
A task could not be started.
Corrective action:
Review the start time of the task. Reconfigure it.
SVmco User Guidel