SVmco User Guide
Execute the SNMP security setting command (setsnmpsec) in the
following situations. For details on the command, see
Setting Command
Having installed SVmco, you will be changing the SNMP
o
Service security setting from [Accept SNMP packets from any host] to
[Accept SNMP packets from these hosts].
You will be changing the MMB IP address.
o
If you change the MMB IP address or the management LAN IP address
on the partition, be sure to then restart SVmco. Otherwise, SVmco would
not be able to report detected errors.
Notes on configuring Windows Server 2008
From [Properties] in the Event Viewer, do not change the operation in
[When maximum log size is reached] for the system log or application log
to [Do not overwrite events (clear log manually)]. Otherwise, after the log
reaches the maximum log size, no errors are output to the log, so SVagent
will be unable to detect any errors.
Do not stop the Windows Print Spooler service. The information
collection function of the operating system uses WMI to collect
configuration information. If the Print Spooler service is stopped, the
function cannot collect the correct configuration information because WMI
reports an error.
If the set value of the following registry key is less than 20000 (20
seconds), the system may hang during operating system shutdown. Be
sure to set a value equal to or greater than 20000 (20 seconds).
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
WaitToKillServiceTimeout" (Type: REG_DWORD /
Default;20000)
You can use the above registry key to specify the wait time (ms) before
the service is terminated in the shutdown sequence.
(setsnmpsec).
3.5 SNMP Security