Fujitsu PRIMEQUEST 1000 Series User Manual page 560

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

SVmco User Guidel
13193
mptscsih: Adapter error (Errata on LSI53C1030 occurred)
Meaning:
Errata No.28 of LSI53C1030 (chip) occurred during reading of the data.
Corrective action:
Reexecute read after converting the target block size of the target data into
multiples of eight.
If the error keeps recurring, collect the data for investigation (dump or fjsnap),
and contact your sales representative or a field engineer.
Severity:
Warning
Action:
(R/M/T/S)
13194
mptscsih:iocx Device error (target reset failed) vendor-id=1000 device-
id=%d revision=%r
Meaning:
The target reset failed.
Corrective action:
Replace the target device. If the error keeps recurring, contact your sales
representative or a field engineer.
Severity:
552