Analog Output Units
Item
Analog
Number of outputs
output sec-
Output signal range
tion
External output allow-
able load resistance
External output
impedance
Resolution
Overall
25°C
accuracy
0 to 55°C
D/A conversion data
Conversion time
Isolation method
Current consumption
Analog Output Signal
Ranges
Note
400
CP1H CPU Unit
Voltage Output
4 outputs (4 words allocated)
1 to 5 VDC,0 to 10 VDC, or –10 to 10 VDC
2 kΩ min.
0.5 Ω max.
1/6000 (full scale)
0.4% full scale
0.8% full scale
16-bit binary (4-digit hexadecimal)
Full scale for –10 to 10 V: F448 to 0BB8 Hex
Full scale for other ranges: 0000 to 1770 Hex
2 ms/point (8 ms/all points)
Photocoupler isolation between analog I/O terminals and internal circuits. No isola-
tion between analog I/O signals.
5 VDC: 80 mA max.; 24 VDC: 124 mA max.
The analog values depend on the output signal ranges, as shown in the fol-
lowing diagrams.
When the output exceeds the specified range, the output signal will be fixed at
either the lower limit or upper limit.
A maximum of 7 Expansion Units or
Expansion I/O Units can be connected.
CPM1A-20EDR1
CPM1A-8ED
Expansion I/O Unit
Expansion I/O Unit
C OM
01
0 3
05
07
09
11
C OM
01
N C
00
02
04
06
08
10
00
02
C H
I N
I N
C H
00 01 02 03 04 05 06 07
C H 00 01 02 03
08 09 10 11
08 09 10 11
20EDR1
OUT
C H 00 01 02 03 04 05 06 07
C H
E X P
N C
00
01
02
04
05
07
04
06
N C
C OM
C O M
C OM
0 3
CO M
06
C OM
0 5
Current Output
0 to 20 mA or 4 to 20 mA
350 Ω max.
---
Section 7-3
CPM1A-DA041
Analog Output Unit
0 3
8ED
E X P
OUT
CH
I OUT1
VOUT2
COM2
I OUT3
VOUT4 COM4
AG
07
VOUT1
COM1
I OUT2
VOUT3
COM3
I OUT4
NC

Advertisement

Table of Contents
loading

Table of Contents