Pulse Outputs
1,2,3...
Instructions Used
Preparation
296
■ System Configuration
Cutter finished
IN 1.06
Built-in I/O other than pulse outputs are used.
■ Operation
1. The workpiece is set at the starting position using the Jogging Switch Input
(IN 1.04).
2. The workpiece is feed the specified distance (relative) using the Position-
ing Switch Input (IN 1.05).
3. When feeding has been completed, the cutter is activated using the Cutter
Start Output (OUT 101.00).
4. Feeding is started again when the Cutter Finished Input (IN 1.06) turns
ON.
5. The feeding/cutting operation is repeated for the number of times specified
for the counter (C0, 100 times).
6. When the operation has been completed, the Cutting Operation Finished
Output (OUT 101.01). is turned ON.
The feeding operation can be canceled and operation stopped at any point
using the Emergency Switch Input (IN 1.07).
SPED(885)
PLS2(887)
■ PLC Setup
There are no settings that need to be made in the PLC Setup.
■ DM Area Settings
Speed Settings for Jogging (D0 to D3)
Setting details
Target frequency: 1,000 Hz
Target frequency: 0 Hz
Cutter start
OUT 101.00
Pulse output (CW/CCW)
Section 5-3
Jogging switch
IN 1.04
Positioning switch
IN 1.05
Emergency stop switch
IN 1.07
Cut operation finished
OUT 101.01
Address
Data
D0
#03E8
D1
#0000
D2
#0000
D3
#0000