Error Classification and Confirmation
CPU Unit Indicators and Error Meanings in RUN or MONITOR Mode
Seven-segment Display
Indicator
CPU
error
standby
POWER
Lit
Lit
RUN
Not lit
Not lit
ERR/ALM
Lit
Not lit
INH
Not lit
---
BKUP
---
---
PRPHL
---
---
Two-digit, 7-segment display
Error codes are shown on the 7-segment display if an error occurs. The 7-
segment display has only two digits, so 4-digit error codes are displayed two
digits at a time. If there are 4-digit error details in addition to the error code,
they will be displayed after the error code two digits at a time.
• Display Example
Error code: 80F1 (memory error)
Error details: 0001 (user program)
8.0.
f.1.
The display switches at intervals of approximately 1 s.
• If two or more errors occur at the same time, the most serious error will be
displayed first. When that error is cleared, the next most serious error will
be displayed.
• The 7-segment display shows digits created by special instructions in the
user program or by analog adjustment operations. Error code displays,
however, are given priority whenever an error occurs.
CPU
Fatal
Non-
error
fatal
error
Lit
Lit
Not lit
Lit
Lit
Flashing ---
---
---
---
---
---
---
0.0.
Section 11-1
Peripheral port
Output
communica-
OFF Bit
tions error
turned ON
Lit
Lit
Lit
Lit
---
---
Lit
---
---
Not lit
---
(Not lit)
0.1.
575