Serial Communications
Type
Header
code
Host Link
XZ
ABORT (command
communi-
only)
cations
**
INITIALIZE (com-
processing
mand only)
commands
IC
Undefined com-
mand
(response only)
FINS Commands
Type
Command
code
I/O Memory
01
01
Area Access
01
02
Commands
01
03
01
04
01
05
Parameter
02
01
Area Access
02
02
Commands
02
03
Program Area
03
06
Access Com-
03
07
mands
03
08
Execution
04
01
Control Com-
04
02
mands
Configuration
05
01
Read Com-
05
02
mands
Status Read
06
01
Commands
06
20
Clock Access
07
01
Commands
07
02
Message
09
20
Access Com-
mands
Access Right
0C
01
Commands
0C
02
0C
03
Error Access
21
01
Commands
21
02
21
03
Forced Status
23
01
Commands
23
02
Name
Aborts the host link command that is currently being processed.
Initializes the transmission control procedure of all PLCs connected to the
host computer.
This response is returned if the header code of a command was not recog-
nized.
The following table lists the FINS commands. Refer to the FINS Commands
Reference Manual (W227) for more details.
Name
MEMORY AREA READ
MEMORY AREA WRITE
MEMORY AREA FILL
MULTIPLE MEMORY AREA
READ
MEMORY AREA TRANSFER
PARAMETER AREA READ
PARAMETER AREA WRITE
PARAMETER AREA FILL
PROGRAM AREA READ
PROGRAM AREA WRITE
PROGRAM AREA CLEAR
RUN
STOP
CONTROLLER DATA READ
CONNECTION DATA READ
CONTROLLER STATUS READ
CYCLE TIME READ
CLOCK READ
CLOCK WRITE
MESSAGE READ/CLEAR
ACCESS RIGHT ACQUIRE
ACCESS RIGHT FORCED
ACQUIRE
ACCESS RIGHT RELEASE
ERROR CLEAR
ERROR LOG READ
ERROR LOG CLEAR
FORCED SET/RESET
FORCED SET/RESET CANCEL Cancels the forced status of all force-set and force-reset
Function
Function
Reads consecutive data from the I/O memory area.
Writes consecutive data to the I/O memory area.
Fills the specified range of I/O memory with the same
data.
Reads non-consecutive data from the I/O memory area.
Copies and transfers consecutive data from one part of
the I/O memory area to another.
Reads consecutive data from the parameter area.
Writes consecutive data to the parameter area.
Fills the specified range of the parameter area with the
same data.
Reads data from the user program area.
Writes data to the user program area.
Clears the specified range of the user program area.
Switches the CPU Unit to RUN or MONITOR mode.
Switches the CPU Unit to PROGRAM mode.
Reads CPU Unit information.
Reads the model numbers of the specified Units.
Reads the CPU Unit's status information.
Reads the average, maximum, and minimum cycle
times.
Reads the clock.
Sets the clock.
Reads/clears messages and FAL (FALS) messages.
Acquires the access right if no other device holds it.
Acquires the access right even if another device cur-
rently holds it.
Releases the access right regardless of what device
holds it.
Clears errors and error messages.
Reads the error log.
Clears the error log pointer to zero.
Force-sets, force-resets, or clears the forced status of
the specified bits.
bits.