Omron CP1H CPU Operation Manual page 712

Cp1h cpu unit
Hide thumbs Also See for CP1H CPU:
Table of Contents

Advertisement

Auxiliary Area Allocations by Address
Addresses
Name
Word
Bits
A738 to
All
Power ON
A740
Clock Data 7
A741 to
All
Power ON
A743
Clock Data 8
A744 to
All
Power ON
A746
Clock Data 9
A747 to
All
Power ON
A749
Clock Data
10
A751
A751.11 DM Initial
Values Read
Error Flag
A751.12 DM Initial
Values Save
Execution
Error Flag
A751.13 DM Initial
Values Save
Error Flag
A751.14 DM Initial
Values Save
Flag
A751.15 DM Initial
Values Save
Start Bit
678
Function
These words contain the time at which
the power was turned ON seven times
before the startup time stored in words
A510 to A511.
A738.00 to A738.07: Seconds (00 to 59)
A738.08 to A738.15: Minutes (00 to 59)
A739.00 to A739.07: Hour (00 to 23)
A739.08 to A739.15: Day of month (00
to 31)
A740.00 to A740.07: Month (01 to 12)
A740.08 to A740.15: Year (00 to 99)
These words contain the time at which
the power was turned ON eight times
before the startup time stored in words
A510 to A511.
A741.00 to A741.07: Seconds (00 to 59)
A741.08 to A741.15: Minutes (00 to 59)
A742.00 to A742.07: Hour (00 to 23)
A742.08 to A742.15: Day of month (00
to 31)
A743.00 to A743.07: Month (01 to 12)
A743.08 to A743.15: Year (00 to 99)
These words contain the time at which
the power was turned ON nine times
before the startup time stored in words
A510 to A511.
A744.00 to A744.07: Seconds (00 to 59)
A744.08 to A744.15: Minutes (00 to 59)
A745.00 to A745.07: Hour (00 to 23)
A745.08 to A745.15: Day of month (00
to 31)
A746.00 to A746.07: Month (01 to 12)
A746.08 to A746.15: Year (00 to 99)
These words contain the time at which
the power was turned ON ten times
before the startup time stored in words
A510 to A511.
A747.00 to A747.07: Seconds (00 to 59)
A747.08 to A747.15: Minutes (00 to 59)
A748.00 to A748.07: Hour (00 to 23)
A748.08 to A748.15: Day of month (00
to 31)
A749.00 to A749.07: Month (01 to 12)
A749.08 to A749.15: Year (00 to 99)
ON when an error occurred in transfer-
ring DM initial values from the DM initial
value area in flash memory to the DM
Area.
ON when the DM Initial Values Transfer
Password (A752) is incorrect or when
the DM Initial values area was not spec-
ified when starting to transfer DM initial
values from the DM Area to the DM ini-
tial value area in flash memory.
ON when an error occurred in transfer-
ring DM initial values from the DM Area
to the DM initial value area in flash
memory.
ON while DM initial values are being
transferred from the DM Area to the DM
initial value area in flash memory.
OFF when the transfer has been com-
pleted.
Turn ON this bit to start transferring DM
initial values. This bit is valid only when
a correct password is stored in A752
and the DM Area Initial Value Area is
specified (i.e., when A753.00 is ON).
The system will turn this bit OFF auto-
matically when the transfer has been
completed.
Settings
Status
Status
after
at star-
mode
change
See at left.
Retained Retained Written
See at left.
Retained Retained Written
See at left.
Retained Retained Written
See at left.
Retained Retained Written
OFF: Normal
Retained Cleared
ON: Error
(failed to load)
OFF: Normal
Retained Cleared
ON: Error
(failed to save)
OFF: Normal
Retained Cleared
ON: Error
(failed to save)
OFF: Not being
Retained Cleared
saved
ON: Being
saved
Turned ON:
Retained Cleared
Transfer
started
OFF: Not trans-
ferring
ON: Transfer-
ring
Appendix D
Write
Related
timing
Flags,
tup
Settings
when
power is
turned
ON.
when
power is
turned
ON.
when
power is
turned
ON.
when
power is
turned
ON.
---
---
---
---
---
---
---
---
---
---

Advertisement

Table of Contents
loading

Table of Contents