Auxiliary Area Allocations by Function
Item
Pulse Output Accel/Decel Flag
Pulse Output Overflow/Underflow Flag
Pulse Output, Output Amount Set Flag
Pulse Output, Output Completed Flag
Pulse Output, Output In-progress Flag
Pulse Output No-origin Flag
Pulse Output At-origin Flag
Pulse Output, Output Stopped Error Flag
PWM Output, Output In-progress Flag
Pulse Output Stop Error Code
Pulse Output Reset Bit
Pulse Output CW Limit Input Signal Flag
Pulse Output CCW Limit Input Signal Flag
Pulse Output Positioning Completed Signal A540.10
Name
Pulse Output PV
Contain the number of pulses output from the correspond-
ing pulse output port. PV range: 80000000 to 7FFFFFFF
hex (-2,147,483,648 to 2,147,483,647)
When pulses are being output in the CW direction, the PV
is incremented by 1 for each pulse.
When pulses are being output in the CCW direction, the PV
is decremented by 1 for each pulse.
PV after overflow: 7FFFFFFF hex
PV after underflow: 80000000 hex
Note
Pulse Output
This flag will be ON when pulses are being output accord-
Accel/Decel Flag
ing to an ACC(888) or PLS2(887) instruction and the output
frequency is being changed in steps (accelerating or decel-
erating).
OFF: Constant speed
ON: Accelerating or decelerating
Pulse Output Over-
This flag indicates when an overflow or underflow has
flow/Underflow Flag
occurred in the pulse output PV.
OFF: Normal
ON: Overflow or underflow
Pulse Output, Output
ON when the number of output pulses has been set with
Amount Set Flag
the PULS(886) instruction.
OFF: No setting
ON: Setting made
Pulse Output, Output
ON when the number of output pulses set with the
Completed Flag
PULS(886) or PLS2(887) instruction has been output.
OFF: Output not completed.
ON: Output completed.
Pulse Output, Output
ON when pulses are being output.
In-progress Flag
OFF: Stopped
ON: Outputting pulses.
622
Pulse output
Pulse output
0
A280.00
A281.00
A280.01
A281.01
A280.02
A281.02
A280.03
A281.03
A280.04
A281.04
A280.05
A281.05
A280.06
A281.06
A280.07
A281.07
A283.00
A283.08
A444
A445
A540.00
A541.00
A540.08
A541.08
A540.09
A541.09
A541.10
Description
If the coordinate system uses relative coordinates
(undefined origin), the PV will be cleared to 0 when
a pulse output starts, i.e. when a pulse output
instruction (SPED(885), ACC(888), or PLS2(887))
is executed.
Pulse output
Pulse output
1
2
A326.00
A327.00
A326.01
A327.01
A326.02
A327.02
A326.03
A327.03
A326.04
A327.04
A326.05
A327.05
A326.06
A327.06
A326.07
A327.07
A326.08
A327.08
A438
A439
A542.00
A543.00
A542.08
A543.08
A542.09
A543.09
A542.10
A543.10
Read/Write
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Appendix C
3
Updated
• Cleared when power is turned
ON.
• Cleared when operation starts.
• Updated each cycle during over-
see process.
• Updated when the PV is
changed by the INI(880) instruc-
tion.
• Cleared when power is turned
ON.
• Cleared when operation starts or
stops.
• Updated each cycle during over-
see process.
• Cleared when power is turned
ON.
• Cleared when operation starts.
• Cleared when the PV is changed
by the INI(880) instruction.
• Updated when an overflow or
underflow occurs.
• Cleared when power is turned
ON.
• Cleared when operation starts or
stops.
• Updated when the PULS(886)
instruction is executed.
• Updated when pulse output
stops.
• Cleared when power is turned
ON.
• Cleared when operation starts or
stops.
• Updated at the start or comple-
tion of pulse output in indepen-
dent mode.
• Cleared when power is turned
ON.
• Cleared when operation starts or
stops.
• Updated when pulse output
starts or stops.