Omron CP1H CPU Operation Manual page 88

Cp1h cpu unit
Hide thumbs Also See for CP1H CPU:
Table of Contents

Advertisement

Specifications
Setting Input Functions in
the PLC Setup
Input
terminal
block
Word
Bit
Normal inputs Interrupt inputs
CIO 0
00
Normal input 0
01
Normal input 1
02
Normal input 2
03
Normal input 3
04
Normal input 4
05
Normal input 5
06
Normal input 6
07
Normal input 7
08
Normal input 8
09
Normal input 9
10
Normal input 10 ---
11
Normal input 11 ---
CIO 1
00
Normal input 12 Interrupt input 4 Quick-response
01
Normal input 13 Interrupt input 5 Quick-response
02
Normal input 14 Interrupt input 6 Quick-response
03
Normal input 15 Interrupt input 7 Quick-response
04
Normal input 16 ---
05
Normal input 17 ---
06
Normal input 18 ---
07
Normal input 19 ---
08
Normal input 20 ---
09
Normal input 21 ---
10
Normal input 22 ---
11
Normal input 23 ---
Note
54
Functions for the normal input terminals in the built-in inputs can be individu-
ally allocated by making selections in the PLC Setup.
Input operation
Quick-
(See note.)
response
inputs
Interrupt input 0 Quick-response
input 0
Interrupt input 1 Quick-response
input 1
Interrupt input 2 Quick-response
input 2
Interrupt input 3 Quick-response
input 3
---
---
---
---
---
---
---
---
---
---
---
---
---
---
input 4
input 5
input 6
input 7
---
---
---
---
---
---
---
---
Set using the MSKS instruction in direct mode or counter mode.
High-speed counter
operation
High-speed counters 0
to 3 set to be used.
---
High-speed counter 2
(phase-Z/reset)
High-speed counter 1
(phase-Z/reset)
High-speed counter 0
(phase-Z/reset)
High-speed counter 2
(phase-A, increment, or
count input)
High-speed counter 2
(phase-B, decrement, or
direction input)
High-speed counter 1
(phase-A, increment, or
count input)
High-speed counter 1
(phase-B, decrement, or
direction input)
High-speed counter 0
(phase-A, increment, or
count input)
High-speed counter 0
(phase-B, decrement, or
direction input)
High-speed counter 3
(phase-A, increment, or
count input)
High-speed counter 3
(phase-B, decrement, or
direction input)
High-speed counter 3
(phase-Z/reset)
---
---
---
---
---
---
---
---
---
---
---
Section 2-2
Origin search function
Origin search function
for pulse outputs 0 to 3
set to be used.
Pulse 0: Origin input sig-
nal
Pulse 0: Origin proximity
input signal
Pulse output 1: Origin
input signal
Pulse output 1: Origin
proximity input signal
---
---
---
---
---
---
---
---
Pulse output 2: Origin
input signal
Pulse output 2: Origin
proximity input signal
Pulse output 3: Origin
input signal
Pulse output 3: Origin
proximity input signal
---
---
---
---
---
---
---
---

Advertisement

Table of Contents
loading

Table of Contents