System Expansion With Cj-Series Units - Omron CP1H CPU Operation Manual

Cp1h cpu unit
Hide thumbs Also See for CP1H CPU:
Table of Contents

Advertisement

System Configuration
1-2-3

System Expansion with CJ-series Units

Required Units
Name
CJ Unit Adapter CP1W-EXT01
Main Connectable CJ-
series Units
Classification
CPU Bus
Units
A maximum of two CJ-series Special I/O Units or CPU Bus Units can be con-
nected. In order to connect them, a CP1W-EXT01 CJ Unit Adapter and a
CJ1W-TER01 End Cover are required. These Units make it possible to add
serial communication functions, such as network communications or protocol
macros.
DIN Track
SYSMAC
IN
CP1H
L1
L2/N
COM
01
03
05
07
BATTERY
00
02
04
06
08
POWER
PERIPHERAL
ERR/ALM
BKUP
MEMORY
00
01
02
03
COM
COM
COM
100CH
OUT
Model
Mounting a CJ Unit Adapter to the right of the
CP1H CPU Unit makes it possible to connect up
to two CJ-series Special I/O Units or CPU Bus
Units.
Note The CJ Unit Adapter comes packaged
The main CPU Bus Units and Special I/O Units that can be connected are
listed in the following table.
Unit name
Ethernet Units
CJ1W-ETN11/21
Controller Link Unit
CJ1W-CLK21-V1
Serial Communica-
CJ1W-SCU21-V1
tions Units
CJ1W-SCU41-V1
DeviceNet Unit
CJ1W-DRM21
PFP-M
End Plates
09
11
01
03
05
07
09
11
10
00
02
04
06
08
10
EXP
04
06
00
01
03
04
06
COM
05
07
COM
02
COM
05
07
101CH
1CH
CJ-series
CP1W-EXT01
CPU Bus Units
CJ Unit Adapter
Special I/O Units
Description
with one CJ1W-TER01 End Cover.
Model
Section 1-2
CJ-series
CJ1W-TER01 End Cover
(Included with CJ Unit
Adapter.)
Weight
40 g max.
Current
Weight
consumption
(5 VDC)
0.38 A
100 g max.
0.35 A
110 g max.
0.28 A
110 g max.
0.38 A
0.29 A
118 g max.
21

Advertisement

Table of Contents
loading

Table of Contents