Omron CP1H CPU Operation Manual page 705

Cp1h cpu unit
Hide thumbs Also See for CP1H CPU:
Table of Contents

Advertisement

Auxiliary Area Allocations by Address
Addresses
Name
Word
Bits
A527
A527.00
Online Edit-
to
ing Disable
A527.07
Bit Validator
A527.09 Online Edit-
ing Disable
Bit
A528
A528.00
Serial Port 2
to
Error Flags
A528.07
A528.08
Serial Port 1
to
Error Code
A528.15
A529
All
FAL/FALS
Number for
System
Error Simu-
lation
A531
A531.00 High-speed
Counter 0
Reset Bit
A531.01 High-speed
Counter 1
Reset Bit
A531.02 High-speed
Counter 2
Reset Bit
A531.03 High-speed
Counter 3
Reset Bit
Function
The Online Editing Disable Bit
(A527.09) is valid only when this byte
contains 5A.
To disable online editing from the
CX-Programmer, set this byte to 5A
and turn ON A527.09.
(Online editing refers to changing or
adding to the program while the PLC
is operating in MONITOR mode.)
Turn this bit ON to disable online
editing. The setting of this bit is valid
only when A527.00 to A527.07 have
been set to 5A.
These flags indicate what kind of
error has occurred at the serial port
2; they are automatically turned OFF
when the serial port 2 is restarted.
(These flags are not valid in periph-
eral bus mode and only bit 5 is valid
in NT Link mode.)
PLC Link Polling Unit:
Bit 05: ON for timeout error.
PLC Link Polled Unit:
Bit 03: ON for framing error.
Bit 04: ON for overrun error.
Bit 05: ON for timeout error.
These bits can be cleared by the CX-
Programmer.
These flags indicate what kind of
error has occurred at the serial port
1; they are automatically turned OFF
when the serial port 1 is restarted.
(These flags are not valid in periph-
eral bus mode and only bit 5 is valid
in NT Link mode.)
PLC Link Polling Unit:
Bit 13: ON for timeout error.
PLC Link Polled Unit:
Bit 11: ON for framing error.
Bit 12: ON for overrun error.
Bit 13: ON for timeout error.
These bits can be cleared by the CX-
Programmer.
Set a dummy FAL/FALS number to
use to simulate the system error
using FAL(006) or FALS(007).
When FAL(006) or FALS(007) is exe-
cuted and the number in A529 is the
same as the one specified in the
operand of the instruction, the sys-
tem error given in the operand of the
instruction will be generated instead
of a user-defined error.
When the reset method is set to
Phase-Z signal + Software reset, the
corresponding high-speed counter's
PV will be reset if the phase-Z signal
is received while this bit is ON.
When the reset method is set to Soft-
ware reset, the corresponding high-
speed counter's PV will be reset in
the cycle when this bit turns ON.
Settings
Status
Status at
after
startup
mode
change
5A:
Retained Cleared
A527.09
enabled
Other value:
A527.09 dis-
abled
ON: Disabled
Retained Cleared
OFF: Not dis-
abled
Bits 00 and 01:
---
---
Not used.
Bit 02: ON for
parity error.
Bit 03: ON for
framing error.
Bit 04: ON for
overrun error.
Bit 05: ON for
timeout error.
Bits 06 and 07:
Not used.
Bits 08 and 09:
---
---
Not used.
Bit 10: ON for
parity error.
Bit 11: ON for
framing error.
Bit 12: ON for
overrun error.
Bit 13: ON for
timeout error.
Bits 14 and 15:
Not used.
0001 to 01FF
Retained Cleared
hex: FAL/FALS
numbers 1 to
511
0000 or 0200
to FFFF hex:
No FAL/FALS
number for sys-
tem error simu-
lation. (No error
will be gener-
ated.)
---
Retained Cleared
---
Retained Cleared
---
Retained Cleared
---
Retained Cleared
Appendix D
Write
Related
timing
Flags,
Settings
---
A527.09
---
A527.00
to
A527.07
---
---
---
---
---
---
---
---
---
---
---
---
---
---
671