5
Programming Command Reference
TESTs Subsystem for Automatic Test
Command Reference for Stand-by/Measuring Screens
5-82
This function allows you to execute the overall measurements
and pass or fail tests by the automatic test. Test sequence and
condition are configured by the CONFigure:SEQuence
command and CONFigure:CONDition command.
The following commands are used to set the controls and
parameters associated with the initial test condition for the
[Stand-by] or [Measuring] screens. The query commands return
the settings of those controls and parameters.
Screen Mode
TESTs:AUTO:SCReen SIMPlified|DETailed|VALue
TESTs:AUTO:SCReen?
This command selects the screen mode. The parameter is
SIMPlified screen, the DETailed screen or the VALue
screen. At preset, this value is set to SIMPlified.
This query command returns the selected screen mode with
strings of SIMP, DET or VAL.
Caller ID
TESTs:AUTO:CALLer:ID <string>
TESTs:AUTO:CALLer:ID?
This command is valid when CDMA mode is set to MC1X. This
sets the Caller ID on the [Stand-by] screen. <string>: Up to 32
digit arbitrary number from 0 to 9 and symbol * or #, without
double quotation. At preset, this value is set to
01234567890123456789.
This is not initialized by PRESET execution with the Starting
Condition softkey.
This query command returns the set Caller ID with string.
N9360A Multi UE Tester CDMA2000 Programming Manual