Parameter Macros - Siemens SINAMICS S150 Operating Instructions Manual

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

A.2

Parameter macros

Parameter macro p0015 = S150 cabinet unit
This macro is used to make default settings for operating the cabinet unit.
Table A-1
Parameter macro p0015 = S150 cabinet unit
Parameter
p0500
Technology application
p0600
Motor temperature sensor for
monitoring
p0601
Motor temperature sensor type
p0603[0]
CI: Motor temperature
p0603[1]
CI: Motor temperature
p0604
Motor overtemperature alarm threshold
p0605
Motor overtemperature fault threshold
p0606
Motor overtemperature timer
p0610
Response to motor overtemperature
condition
p0700[0]
Macro binector input (BI)
p0857
Power module monitoring time
p0864
BI: Infeed operation
p1000[0]
Macro connector inputs (CI) for speed
setpoints
p1001
CO: Fixed speed setpoint 1
p1002
CO: Fixed speed setpoint 2
p1003
CO: Fixed speed setpoint 3
p1083
CO: Speed limit in positive direction of
rotation
p1086
CO: Speed limit in negative direction
of rotation
p1115
Ramp-function generator selection
p1120
Ramp-function generator ramp-up time Vector 20 s
p1121
Ramp-function generator ramp-down
time
p1135
OFF3 ramp-down time
p1200
FlyRest oper mode
p1208.0
BI: WEA infeed fault
p1208.1
BI: WEA infeed supply break
p1240
Vdc controller configuration
p1280
Vdc controller configuration (U/f)
p1300
Open-loop/closed-loop control
operating mode
p1911
Number of phases to be identified
p2051[0]
CI: PROFIBUS PZD send word
p2051[1]
CI: PROFIBUS PZD send word
p2051[2]
CI: PROFIBUS PZD send word
p2051[3]
CI: PROFIBUS PZD send word
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
Sink
Description
DO
Parameter
Vector 0
Standard drive
Vector 0
No sensor
Vector 0
No sensor
Vector r4105
Sensor on TM31
Vector
Vector 120
(Factory setting)
Vector 155
(Factory setting)
Vector 0
(Factory setting)
Vector 1
Display fault, for alarm Imax red.
Vector 70006
TM31 terminals
Vector 30000
30 seconds
Vector r0863.0
Vector 10002
TM31_AI0
Vector 300 rpm
Vector 600 rpm
Vector 1500 rpm
Vector 6000 rpm
Vector -6000 rpm
Vector 1
Extended RFG
Vector 30 s
Vector 10 s
Vector 0
Flying restart not active
Vector r2139.3
Fault active
Vector r0863.2
Drive link - infeed supply break
Vector 0
Disable Vdc-max controller
Vector 0
Disable Vdc-max controller
Vector 20
Sensorless speed control
Vector 3
3 phases
Vector r2089[0]
STW1
Vector r0063
n-act
Vector r0068
I-act
Vector r0080
M-act
Appendix
A.2 Parameter macros
Source
Description
DO
Vector
Vector
Vector
TM31
Vector
Vector
Vector
Vector
Vector
Vector
A_Inf
Vector
Vector
Vector
Vector
Vector
Vector
Vector
Vector
Vector
Vector
Vector
A_INF
A_INF
Vector
Vector
Vector
Vector
Vector
Vector
Vector
Vector