Commissioning
5.3 Procedure for commissioning via STARTER
34. To enter special encoder configurations, click the Enter data radio button and then the
Encoder data button. The following screen (in this case an example for the HTL encoder) is
displayed in which you can enter the required data.
Figure 5-27
Entering encoder data – user-defined encoder data – example: HTL encoder
35. Enter the required encoder data.
36. Click OK.
CAUTION
Option K50: once the encoder has been commissioned, the supply voltage (5/24 V) set for
the encoder is activated on the SMC30 module. If a 5 V encoder is connected and the
supply voltage has not been set correctly, the encoder may be damaged.