Siemens SINAMICS S150 Operating Instructions Manual page 213

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

Bit
Meaning
15
Alarm, drive converter thermal
overload
Status word 1 (interface mode PROFIdrive VIK-NAMUR, p2038 = 2)
Table 6-16
Status word 1 (interface mode PROFIdrive VIK-NAMUR, p2038 = 2)
Bit
Meaning
0
Ready to power up
1
Ready
2
Operation enabled
3
Fault active
4
No OFF2 active /
coasting active (OFF2)
5
0 = Fast stop active (OFF3)
6
Power-on disable
7
Alarm present
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
1
No alarm present
0
Alarm, drive converter thermal overload
The overtemperature alarm for the converter is active.
1
Ready to power up
Power supply on, electronics initialized, line contactor
released if necessary, pulses inhibited.
0
Not ready to power up
1
Ready
Voltage at Line Module (i.e. line contactor closed (if used)),
field being built up.
0
Not ready
Cause: No ON command has been issued.
1
Operation enabled
Enable electronics and pulses, then ramp up to active
setpoint.
0
Operation inhibited
1
Fault active
The drive is faulty and is, therefore, out of service. The drive
switches to Power-on inhibit once the fault has been
acknowledged and the cause has been remedied.
The active faults are stored in the fault buffer.
0
No fault present
There is no active fault in the fault buffer.
1
No OFF2 active
0
Coasting active (OFF2)
An OFF2 command is present.
1
No OFF3 active
0
Coasting active (OFF3)
An OFF3 command is present.
1
Power-on disable
A restart is only possible through OFF1 followed by ON.
0
No power-up inhibit
Power-up is possible.
1
Alarm present
The drive is operational again. No acknowledgement
necessary.
The active alarms are stored in the alarm buffer.
Explanation
Explanation
Operation
6.6 PROFIBUS
BICO
BO: r2135.15
BICO
BO: r0899.0
BO: r0899.1
BO: r0899.2
BO: r2139.3
BO: r0899.4
BO: r0899.5
BO: r0899.6
BO: r2139.7