Siemens SINAMICS S150 Operating Instructions Manual page 410

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

Diagnosis / faults and alarms
10.2 Diagnosis
Customer Terminal Block TM31 (-A60)
Table 10-2
Description of the LEDs on the TM31
LED
Color
RDY
---
Green
Orange
Red
Green / red
Green orange
or
red orange
410
State
OFF
The electronics power supply is missing or lies outside permissible
tolerance range.
Steady light
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
Steady light
DRIVE-CLiQ communication is being established.
Steady light
At least one fault is pending on this component.
Note:
LED is driven irrespective of the corresponding messages being
reconfigured.
0.5 Hz flashing
Firmware is being downloaded.
light
2 Hz flashing
Firmware download is complete. Waiting for POWER ON.
light
2 Hz flashing
Detection of the components via LED is activated (p0154).
light
Note:
Both options depend on the LED status when module recognition is
activated via p0154 = 1.
Description
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A

Advertisement

Table of Contents
loading