Jog

Description
Parameter p2591 can be used to switch between "Incremental jog" and "Jog velocity".
Jog signals p2589 and p2590 are used to specify the travel distances p2587 and/or p2588
and the velocities p2585 and p2586. The travel distances are only effective when the "1"
signal is at p2591 (incremental jog). When p2591 = "0", the travel range start or the travel
range end is approached at the specified velocity.