Siemens SINAMICS S150 Operating Instructions Manual page 65

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

S5: Selector for voltage/current AI0, AI1
Table 4-13
Selector for voltage/current S5
Switch
S5.0
Selector voltage/current AI0
S5.1
Selector voltage/current AI1
X522: 2 analog outputs, temperature sensor connection
Table 4-14
Terminal block X522
Terminal
1
2
3
4
5
6
7
8
AO: analog output; KTY: temperature sensor connection
1)
Max. connectable cross-section: 1,5 mm² (AWG 14)
X 540: Joint auxiliary voltage for the digital inputs
Table 4-15
Terminal block X540
Terminal
1
2
3
4
5
6
7
8
Max. connectable cross-section: 1.5 mm² (AWG 14)
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
Function
Designation
1)
AO 0 V+
AO 0 ref.
AO 0 A+
AO 1 V+
AO 1 ref.
AO 1 A+
KTY+
KTY-
Designation
P24
P24
P24
P24
P24
P24
P24
P24
Technical specifications
Voltage
Technical specifications
-10 V - +10 V
+4 mA - +20 mA
-20 mA - +20 mA
0 mA - +20 mA
KTY84: 0...200°C
PTC: R
≤ 1,5 kΩ
cold
Technical specifications
24 V DC
Imax = 150 mA (total of all P24 terminals)
Continued-short-circuit-proof
Electrical installation
4.8 Signal connections
Current
65

Advertisement

Table of Contents
loading

Table of Contents