Electrical installation
4.2 Checklist for electrical installation
Item
Activity
17
Option K48
SMC20 Sensor
Module
18
Option K50
SMC30 Sensor
Module
Connecting protection and monitoring devices
19
Option L45
EMERGENCY
STOP
pushbutton
20
Option L57
EMERGENCY
STOP category
0
(230 V AC /
24 V DC)
21
Option L59
EMERGENCY
STOP category
1
(230 V AC)
22
Option L60
EMERGENCY
STOP category
1
(24 V DC)
23
Option
L61/L62/L64/L6
5
25/50 kW
braking unit
44
The SMC20 Sensor Module is used for determining the actual motor
speed and the path length.
The following encoders are supported by the SMC20 Sensor Module:
Incremental encoder sin/cos 1Vpp
Absolute encoder EnDat
(See "Electrical installation / SMC20 Sensor Module for detecting the
actual motor speed and the path length (option K48)".)
The SMC30 Sensor Module is used for determining the actual motor
speed.
The following encoders are supported by the SMC30 Sensor Module:
TTL encoder
HTL encoder
SSI encoder
(See "Electrical installation / SMC30 Sensor Module for detecting the
actual motor speed (option K50)".)
The contacts for the EMERGENCY STOP pushbutton are connected
to terminal -X120 and can be picked off so that they can be integrated
in a higher-level line-side protection concept ("Electrical installation /
EMERGENCY STOP pushbutton (option L45)").
EMERGENCY STOP category 0 stops the drive in an uncontrolled
manner. No additional wiring is necessary when implemented in
conjunction with option L45.
If the cabinet unit is integrated in an external safety circuit, however,
the contact must be looped in via terminal block -X120 ("Electrical
installation / EMERGENCY STOP category 0; 230 V AC / 24 V DC
(option L57)").
EMERGENCY STOP category 1 stops the drive in a controlled
manner. No additional wiring is necessary when implemented in
conjunction with option L45. If the cabinet unit is integrated in an
external safety circuit, however, the contact must be looped in via
terminal block –X120 (see "Electrical installation / EMERGENCY
STOP category 1; 230 V AC (option L59)").
EMERGENCY STOP category 1 stops the drive in a controlled
manner. No additional wiring is necessary when implemented in
conjunction with option L45. If the cabinet unit is integrated in an
external safety circuit, however, the contact must be looped in via
terminal block –X120 (see "Electrical installation / EMERGENCY
STOP category 1; 24 V DC (option L60)").
The connecting cables and ground for the braking resistor must be
connected to terminal block –X5: 1/2. A connection must be
established between the braking resistor thermostatic switch and
customer terminal block –A60. When commissioning via AOP30, the
settings for evaluating "external fault 3" must be made. The settings
for evaluating the thermostatic switch as "external fault 2" must be
made (see "Electrical installation / 25 kW Braking unit (option
L61/L64); 50 kW Braking unit (option L62/L65)").
Fulfilled/Complete
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A