Device overview
2.5 Type plate
Type plate data (from type plate above)
Table 2-2
Data on the type plate
Specification
Input
Output
Temperature range
Degree of protection
Duty class
Cooling method
Weight
Explanation of the option short codes
Table 2-3
Explanation of the option short codes
Input options
L26
Main circuit breaker incl. fuses for output currents < 800 A
Output options
L08
Motor reactor
L10
dV/dt filter with Voltage Peak Limiter
L15
Sinusoidal filter (only for the voltage range 380 V - 480 V 3 AC to 200 kW)
Input and output options
M70
EMC shield bus (cable connection from below)
Motor protection and safety functions
L45
EMERGENCY STOP pushbutton in cabinet door
L57
EMERGENCY STOP category 0 (230 V AC or 24 V DC, uncontrolled stop)
L59
EMERGENCY STOP category 1, 230 V AC, controlled stop
L60
EMERGENCY STOP category 1 (24 V DC, controlled stop)
L83
Thermistor motor protection unit with PTB approval (alarm)
L84
Thermistor motor protection unit with PTB approval (shutdown)
L86
PT100 evaluation unit (for 6 PT100 sensors)
L87
Insulation monitoring
M60
Additional shock-hazard protection
26
Value
3 AC
Three-phase connection
380 – 480 V
Rated input voltage
239 A
Rated input current
3 AC
Three-phase connection
0 – 480 V
Rated output voltage
210 A
Rated output current
0 – 40 °C
Ambient temperature range within which the cabinet unit can operate under 100
% load
IP20
Degree of protection
I
I: Duty class I to EN 60146-1-1 = 100 % (continuously)
(with the specified current values, the cabinet unit can operate continuously
under 100 % load)
AF
A: Cooling medium: air
F: circulation method: forced cooling, drive unit (fan) in the device
Weight of the cabinet unit
Explanation
Drive converter cabinet units