Siemens SINAMICS S150 Operating Instructions Manual page 511

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

Parameter macro p1000 = 1: PROFIdrive (100001)
This macro is used to set the default setpoint source via PROFIdrive.
Table A-6
Parameter macro p1000 = 1: PROFIdrive
Parameters
p1070
Main setpoint
p1071
Main setpoint scaling
p1075
Supplementary setpoint
p1076
Supplementary setpoint scaling
Parameter macro p1000 = 2: Terminal TM31 (100002)
This macro is used to set analog input 0 on customer terminal block TM31 as the setpoint
source.
Table A-7
Parameter macro p1000 = 2: TM31 terminals
Parameters
p1070
Main setpoint
p1071
Main setpoint scaling
p1075
Supplementary setpoint
p1076
Supplementary setpoint scaling
Parameter macro p1000 = 3: Motorized potentiometer (100003)
This macro is used to set the motorized potentiometer as the setpoint source.
Table A-8
Parameter macro p1000 = 3: Motorized potentiometer
Parameters
p1070
Main setpoint
p1071
Main setpoint scaling
p1075
Supplementary setpoint
p1076
Supplementary setpoint scaling
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
Sink
Description
Sink
Description
Sink
Description
DO
Parameters
Vector
r2050[1]
PROFIdrive PZD2
Vector
1
100 %
Vector
0
Vector
1
100 %
DO
Parameters
Vector
r4055
AI0 TM31
Vector
1
100 %
Vector
0
Vector
1
100 %
DO
Parameters
Vector
r1050
Motorized potentiometer
Vector
1
100 %
Vector
0
Vector
1
100 %
Appendix
A.2 Parameter macros
Source
Description
Source
Description
Source
Description
DO
Vector
Vector
Vector
Vector
DO
TM31
TM31
TM31
TM31
DO
Vector
Vector
Vector
Vector
511