Siemens SINAMICS S150 Operating Instructions Manual page 293

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

Motor data for permanent-field synchronous motors
Table 7-2
Motor data type plate
Parameter
p0304
Rated motor voltage
p0305
Rated motor current
p0307
Rated motor power
p0310
Rated motor frequency
p0311
Rated motor speed
p0314
Motor pole pair number
p0316
Motor torque constant
If details of the torque constant k
can calculate them as follows from the rated motor data or from the zero-speed current I
and zero-speed torque M0:
k
T
The optional motor data can be entered if it is known. Otherwise, this data is estimated from
the type plate data or determined by means of motor identification or speed controller
optimization.
Table 7-3
Optional motor data
Parameter
p0320
Rated motor short-circuit current
p0322
Maximum motor speed
p0323
Maximum motor current
p0325
Rotor position identification current, 1st phase
p0327
Optional load angle
p0328
Reluctance torque constant
p0329
Rotor position identification current
p0341
Motor moment of inertia
p0344
Motor weight
p0350
Stator resistance, cold
p0356
Quadrature axis stator inductance Lq
p0357
In-line stator inductance Ld
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
Description
×
s
60
P
M
N
=
N
=
min
k =
T
π
×
×
or
I
2
n
I
N
N
N
Description
7.4 Vector speed/torque control with/without encoder
If this value is not known, the value "0" can also be
entered.
Entering the correct value, however, means that the
stator leakage inductance (p0356, p0357) can be
calculated more accurately.
If this value is not known, the value "0" can also be
entered.
If this value is not known, the value "0" can also be
entered.
are not provided on the type plate or in the data sheet, you
T
M
0
I
0
This is used for the field weakening characteristic
Maximum mechanical speed
De-magnetization protection
-
Optional otherwise leave at 90°
-
-
For speed controller pre-control
-
-
-
-
Setpoint channel and closed-loop control
Remark
Remark
0
293