Siemens SINAMICS S150 Operating Instructions Manual page 212

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

Operation
6.6 PROFIBUS
Bit
Meaning
3
Fault active
4
No OFF2 active /
coasting active (OFF2)
5
0 = Fast stop active (OFF3)
6
Power-on disable
7
Alarm present
8
Speed setpoint/actual value
deviation within tolerance
bandwidth
9
Control requested for PLC
"1" is always present
10
f or n comparison value reached
or exceeded
Note:
The message is parameterized as follows:
p2141 Threshold value
p2142 Hysteresis
11
I, M or P limit not reached /
I, M or P limit reached
12
Reserved
13
Alarm, motor overtemperature
14
Motor rotates forwards
(n_act >= 0)
212
1
Fault active
The drive is faulty and is, therefore, out of service. The drive
switches to Power-on inhibit once the fault has been
acknowledged and the cause has been remedied.
The active faults are stored in the fault buffer.
0
No fault present
There is no active fault in the fault buffer.
1
No OFF2 active
0
Coasting active (OFF2)
An OFF2 command is present.
1
No OFF3 active
0
Coasting active (OFF3)
An OFF3 command is present.
1
Power-on disable
A restart is only possible through OFF1 followed by ON.
0
No power-up inhibit
Power-up is possible.
1
Alarm present
The drive is operational again. No acknowledgement
necessary.
The active alarms are stored in the alarm buffer.
0
No alarm present
No active alarm is present in the alarm buffer.
1
Setpoint/actual value monitoring within tolerance bandwidth
Actual value within tolerance band; dynamic overshoot or
shortfall permitted for t < tmax, tmax can be parameterized.
See FP8010
0
Setpoint/actual value monitoring not within tolerance band
1
Control from the PLC
0
Local operation
1
f or n comparison value reached or exceeded
0
f or n comparison value not reached
1
I, M or P limit not reached
0
I, M or P limit reached
1
Motor overtemperature alarm active
0
Motor overtemperature alarm not active
1
Motor rotates forward (n_act ≥ 0)
0
Motor does not rotate forward (n_act < 0)
Explanation
Operating Instructions, 07/07, A5E00288214A
BICO
BO: r2139.3
BO: r0899.4
BO: r0899.5
BO: r0899.6
BO: r2139.7
BO: r2197.7
BO: r0899.9
BO: r2199.1
BO: r1407.7
BO: r2135.14
BO: r2197.3
Drive converter cabinet units

Advertisement

Table of Contents
loading

Table of Contents