M80W, Non-Windows-Based Display (8.4-Type /10.4-Type /15-Type) - Mitsubishi Electric M800W Series Connection And Set Up Manual

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
2 General Connection Diagram

2.2.3 M80W, Non-Windows-based Display (8.4-type /10.4-type /15-type)

Dotted lines indicate the sections prepared by the machine tool builder.
<> Angle brackets indicates attached cable of unit.
L1 L2 L3
No-fuse breaker
(NFB)
ON
OFF
MC
MC
MC
24VDC stabilized
power supply
DCOUT
ACIN
FG
CP
(Note 1)
Drive units
Handy terminal
G430
(Note 1) For information on how to connect the drive unit, refer to the drive unit's manual.
(Note 2) For the connection of machine operation panel, refer to the chapter "Connection of Machine Operation Panel".
(Note 3) When connecting a remote I/O unit to the 3rd RIO channel, insert it between the control unit and operation
panel I/O unit.
(Note 4) There is no need to connect a terminator R2-TM to the graphic control unit.
(Note 5) For the 8.4-type display unit, TP connector is not used.
(Note 6) When the handle of handy terminal is used, connect ENC connector of G430 cable to MPG connector of the
operation panel I/O unit.
Because the pin assignment of ENC connector of G430 is different from that of MPG connector of the
operation panel I/O unit, conversion is required.
The conversion cable needs to be prepared by the MTB.
Graphic control unit
FCU8-GC211
J170
ON
ENC
OFF
RS232C
device
SIO
J303
LAN1
Network
J303
LAN2
Emergency
EMG
stop switch
(Note 4)
J070/071
DCIN
CJ71
24VDC
J010
Operation panel I/O unit
24VDC
CJ71
FG
J210
RIO3EXT
FCU8-DX2xx/DX6xx/DX4xx
max. 29 units
Remote I/O unit
24VDC
DCIN
DI:CJ31/33
J070/071
DO:CJ32/34
J210
RIO1
RIO2
24VDC
(Note 3)
J210
RIO3
GDI
J395/J396
OPTH1
J395/J396
OPTH2
J100
Skip signal input
SKIP
Max. 8 points
RS232C
1ch:J030
device
2ch:J031
SIO
2ch
Emergency
J120
EMG
stop switch
J070/071
DCIN
24VDC
SD
memory
SD
SD
card
BTBOX
<J09x>
LCD
8.4-type:FCU8-DU121-12
<J08x>
10.4-type:FCU8-DU141-32
BL
15-type:FCU8-DU181-32
<J421>
TP
(Note 5)
MENUKEY
Front memory I/F card
USB_F
SDC_F
FRONT
USB_B
RIO1
Memory mediums
SDC_B
<G402>
FCU8-DX730
NCKB
5V:J023/J024/J025
12V:J020/J021/J022
MPG
Machine operation panel
made by the machine tool builder
J350/351
CG31
J350/351
CG32
J350/351
CG33
J350/351
CG34
Machine operation panel (Note 2)
FCU8-KB92x
FCU8-KB941/KB931
<G460>
Control unit
FCU8-MU044
Remote I/O unit
24VDC
DCIN
DI:CJ31/33
J070/071
DO:CJ32/34
J210
RIO1
RIO1
RIO2
Remote I/O unit
24VDC
DCIN
DI:CJ31/33
J070/071
DO:CJ32/34
J210
RIO2
RIO1
RIO2
FCU8-DX2xx/DX6xx /DX4xx
RIO4/M
J303
LAN
Stored in control unit
Function
expansion unit
EXT1
FCU8-EX54x
Communication
expansion unit
EXT3
FCU8-EX56x
9
Display unit
Menu key
Keyboard unit
FCU8-KB02x/04x/083
Manual pulse
generator (5V/12V)
24VDC
Remote I/O unit
J350/351
24VDC
Machine
control
DCIN
DI:CJ31/33
J350/351
relay/contact
J070/071
DO:CJ32/34
To the next
RIO1
RIO2
remote I/O or
terminator
connector
(R2-TM)
Remote I/O unit
24VDC
J350/351
Machine
control
DCIN
DI:CJ31/33
J350/351
relay/contact
J070/071
DO:CJ32/34
To the next
RIO1
RIO2
remote I/O or
terminator
connector
Max. 32 units for each port
(R2-TM)
Energy measuring units
(EcoMonitor)
Network
IB-1501268-K

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents