M800W/M80W Series Connection and Setup Manual
18 Cable
18.2.14 J120 Cable
Max. cable length: 30m
Application: Emergency stop cable
EMG
[EMG]
Connector : 50-57-9403
(former model number: 51030-0330)
Contact
: 0016020103
(former model number: 50084-8129)
Manufacturer: MOLEX
18.2.15 J121 Cable
Max. cable length: 30m
Application: Emergency stop cable for machine operation panel
EMG
[EMG]
Connector : 50-57-9403
Contact
: 0016020103
Manufacturer: MOLEX
EMG
COM
3
EMG IN
2
FG
1
Wire material :
2464C BIOS-CL3-22 01P
Manufacturer: BANDO DENSEN
Red
EMG
COM
3
EMG IN
2
FG
1
Wire material :
2464C BIOS-CL3-22 01P
Manufacturer: BANDO DENSEN
24V
EMG
R1.25-3
Crimp terminal : R1.25-3 × 2
Manufacturer: JST
Faston terminal#110
White
Crimp terminal : Faston terminal #110 with insulating coating
383
24V
EMG
24V
EMG
24V
EMG
IB-1501268-K