Machine End Stopper Method: Manual Initialization - Mitsubishi Electric M800W Series Connection And Set Up Manual

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
25 Setting the Position Detection System

25.1.4 Machine End Stopper Method: Manual Initialization

(1)
Preparations
Set the parameters on the Abs pos
param screen.
(2)
Turn the power OFF and ON.
(Only when "#2049 type" is specified again.)
The following are the operations on the absolute position setting screen. (Select [Mainte] - [To Abs pos])
(3)
Select an axis to set the absolute
position.
There are two methods to select an
axis.
- Select the menu [Axis select], enter
the axis name in the input area then
press [INPUT]. (For the axis name,
input the name set to the parameter
"#1022 axname2" (2nd axis name).)
- Press the menu [Prev axis] and [Next
axis] to switch the axis.
(4)
Select "HANDLE" or "JOG" for the
mode selection of machine operation
switch.
(5)
Confirm that the cursor is placed on
"Absolute posn set", input "1" in the
input area and press the [INPUT] key.
(6)
When the parameter "#2059 zerbas"
is set to "0", set "Zero-P" here. (*2)
Move the cursor to "Zero-P" with
the [ ↑ ] and [ ↓ ] keys.
Input the distance from the basic
machine coordinate zero point to the
machine end stopper in the input area
then press [INPUT].
#2049 type (absolute position detection method): 1 (stopper method)
#2054 clpush (current limit): 0 to 100 (*1)
#2059 zerbas (select zero point parameter and basic point): 0 or 1 (*2)
The parameters other than "#2049 type" can also be set on Absolute
position setting screen.
The input value is registered in the "Absolute posn set" area.
The input value is registered in the "Zero-P" area.
493
Selected axis
IB-1501268-K