Mitsubishi Electric M800W Series Connection And Set Up Manual page 171

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
4 General Specifications
(a) Outline of digital signal output circuit
Use within the specification ranges shown below.
Output circuit
Source output
Output conditions
Insulation method
Rated load voltage
Max. output current
Output delay time
(Note 1) When using an inductive load such as a relay, always connect a diode (voltage resistance
Source output
IB-1501268-K
24VDC
CJ32/CJ34
Load
Y00
Y2F
100V or more, twice or more the load current) in parallel to the load.
24VDC
Inductive load
Y
Diode
Control
circuit
Non-insulation
24VDC
0.2A/point
3.2A or less in the whole unit
40μs
Control
circuit
132

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents