4 General Specifications

4.1 Environment Conditions [M800W]

4.1.1 Environment Conditions inside the Operation Panel

Unit name
Item
Ambient
temperature
Ambient
humidity
Vibration resistance
Shock resistance
Working atmosphere
Altitude
Power supply voltage
General
Specifications
Current consumption
Maximum
heating value
Mass
Outline
dimension
W×H
or
W×H×D
(Note 1) "Short term" means within one month.
(Note 2) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000
meters above sea level. Refer to the manual of drive unit for details.
(Note 3) When the display unit is mounted on an incline, the inclination angle to place the unit should follow below.
10.4 or 15-type display unit: the inclination should be 30 degrees or less from the vertical direction.
19-type display unit: the inclination should be 60 degrees or less from the vertical direction.
IB-1501268-K
FCU8-DU141-31 : (10.4-type)
FCU8-DU181-31 : (15-type)
Type
FCU8-DU181-34 : (15-type)
FCU8-DU191-75 : (19-type)
FCU8-DU192-75 : (19-type)
During
operation
During
storage
Long term
Short term
FCU8-DU141-31 : 12VDC/5VDC/3.3VDC
FCU8-DU181-31 : 12VDC/5VDC/3.3VDC
FCU8-DU181-34 : 12VDC/5VDC/3.3VDC
FCU8-DU191-75 : 12VDC/5VDC
FCU8-DU192-75 : 12VDC/5VDC
(Supply from personal computer unit or
graphic control unit)
FCU8-DU141-31 : 10
FCU8-DU181-31 : 14
(W)
FCU8-DU181-34 : 18
FCU8-DU191-75 : 21
FCU8-DU192-75 : 21
FCU8-DU141-31 : 1.7
FCU8-DU181-31 : 4
(kg)
FCU8-DU181-34 : 4
FCU8-DU191-75 : 5.7
FCU8-DU192-75 : 5.7
FCU8-DU141-31 : 290×220
FCU8-DU181-31 : 400×320
(mm)
FCU8-DU181-34 : 400×320
FCU8-DU191-75 : 365×440
FCU8-DU192-75 : 440×365
Personal computer
Display unit
0 to 58°C
-20 to 60°C
10 to 75% RH (with no dew condensation)
10 to 95% RH (with no dew condensation) (Note 1)
2
4.9m/s
[0.5G] or less
2
29.4m/s
[3G] or less
No corrosive gases, dust or oil mist
Operation/Storage: 1000 meters or less above sea level,
Transportation: 13000 meters or less above sea level
24V 2.2A
22
Graphic control unit
unit
FCU8-PC231
FCU8-GC211
24VDC
24VDC
24V 2.5A
32
12
1.2
1.1
237×182×53.5
239.1×173.4×75