4 General Specifications
[LED]
(1)
(2)
(3)
(4)
No.
Name
(1)
24VDCIN
(2)
DCOUT
(3)
LCDON
(4)
ERR
Lamp state
Lit (Green)
24VDC power is being supplied from the external power supply.
The following may have caused an error:
- No 24VDC-power supply from the external power supply.
Not lit
- Disconnection of fuse near DCIN connector.
- Failure of LED.
Lit (Green)
Internal voltage is normally output.
The followings may have caused an error:
- No 24V-power supply from the external power supply.
Not lit
- Failure in any of the power output circuits.
- Failure of LED or IC which helps turn the LED ON.
Lit (Green)
12VDC for the backlight of display unit is normally output.
The followings may have caused an error:
Not lit
- Failure of 12VDC output in control unit.
- 24VDC input voltage is +20V or less.
H/W is not operating properly. The followings may have caused an error:
Lit (Red)
- Occurrence of NC watchdog error.
- Failure of main CPU card.
Not lit
H/W is operating properly.
87