M800W/M80W Series Connection and Setup Manual
4 General Specifications

4.10 Operation Panel I/O Unit

4.10.1 List of Units

Classification
DI 24V/0V common input [64 points]
DO Source output [64 points]
DI 24V/0V common input [64 points]
DO Source output [64 points]
Scan input [64 points]
Scan output [64 points]
DI 24V/0V common input [64 points]
DO Source output [64 points]
Safety DI 24V/0V common input [8 points]
DI 24V/0V common input [64 points]
DO Source output [64 points]
(Note)
The connection method of DO (CG32/CG34) of FCU8-DX834 is different from other operation panel I/O units.
Be careful not to connect to a wrong connector. See the descriptions mentioned in the later section for more
specific explanation on connections.
Type
Components
Base card
FCU8-DX830
Add-on card
RIO 2.0 terminator connector (R2-TM)
Base card
FCU8-DX834
Add-on card
(Note)
RIO 2.0 terminator connector (R2-TM)
Base card
FCU8-DX837
Add-on card
RIO 2.0 terminator connector (R2-TM)
Base card
FCU8-DX730
RIO 2.0 terminator connector (R2-TM)
97
Remarks
DI: 64-points 24V/0V common type
DO: 64-points source type (200mA/point)
Manual pulse generator input: 3ch
Display unit I/F
Keyboard unit I/F
Emergency stop input
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 4, 7 to 14, 20 to 22
RIO extensible stations:
5, 6, 15 to 19, 23 to 64
(Note) J291 cable is required for connection with
the personal computer unit.
(for windows-based display)
DI: 64-points 24V/0V common type
DO: 64-points source type (200mA/point)
Scan input: 64 points
Scan output: 64 points
Manual pulse generator input: 3ch
Display unit I/F
Keyboard unit I/F
Emergency stop input
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 4, 7 to 14, 20 to 22
RIO extensible stations:
5, 6, 15 to 19, 23 to 64
(Note) J291 cable is required for connection with
the personal computer unit.
(for windows-based display)
DI: 64-points 24V/0V common type
DO: 64-points source type (200mA/point)
Safety DI: 8-points 0V common type
Manual pulse generator input: 3ch
Display unit I/F
Keyboard unit I/F
Emergency stop input
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 4, 7 to 14, 20 to 22
RIO extensible stations:
5, 6, 15 to 19, 23 to 64
(Note) J291 cable is required for connection with
the personal computer unit.
(for windows-based display)
DI: 64-points 24V/0V common type
DO: 64-points source type (200mA/point)
Manual pulse generator input: 3ch
Graphic control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1, 2, 7 to 12, 20 to 22
RIO extensible stations:
3 to 6, 15 to 19, 23 to 64
(13 and 14 are occupied by the graphic control
unit.)
(Note) J010 cable is required for connection with
the graphic control unit.
(for non-Windows-based display)
IB-1501268-K