25 Setting the Position Detection System
(7)
Move the axis to the mechanical basic
position.
(8)
Move the cursor to "Origin-P" with
the [ ↑ ] and [ ↓ ] keys.
Input "1" in the input area and press
the [INPUT] key.
The zero point initial setting is now complete. After initializing all axes, turn the power OFF and ON.
Basic machine coordinate
system zero point
Zero return parameter
"#2037 G53ofs"
(Note 1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P", and then
turn the power OFF and ON.
IB-1501268-K
The input value is registered in the "Origin-P" area.
State: [Complete]
Machine end: 0.000
Machine position: Value set for "Zero-P"
Start point
Reference
position
"#2 Zero-P"
(7)
Mechanical basic
position