Mitsubishi Electric M800W Series Connection And Set Up Manual page 193

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
4 General Specifications
(a-1) Outline of voltage input circuit
Input circuit
Input conditions
Set the input signal within the range as shown in the conditions below.
Input voltage range
Max. input rating
Resolution
Max. input delay (AI input to R register
output)
Disconnection detection function
Precision
(a-2) Outline of current input circuit
Input circuit
Input conditions
Set the input signal within the range as shown in the conditions below.
Input current range
Max. input rating
Resolution
Max. input delay (AI input to R register
output)
Disconnection detection function
Precision
IB-1501268-K
Voltage
source
Current
source
FCU8-DX409
AI
V+
V-
FG
FG
-10V to +10V
±13V
|-10V to +10V| / 64000 = 312.5μV
40ms
Not provided
± 0.5%FS (FS : Full Scale)
FCU8-DX409
AI
I+
I-
FG
FG
-20mA to +20mA
±30mA
|-20mA to +20mA| / 32000 = 1.25μA
40ms
Not provided
±0.5%FS (FS : Full Scale)
154
ADC
ADC

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents