Mitsubishi Electric M800W Series Connection And Set Up Manual page 375

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
12 Connection of Remote I/O Unit
[Thermistor cable connecting procedure]
The thermistor cable has the following configuration:
Thermistor
(1) Solder the thermistor to the shield cable and cover the joint surface with the protection tube.
(2) Twist the shield of the cable or pull out the drain wire.
(3) Insert the wire into the THERMISTOR connecter as follows:
1 pin: Twisted shield wire or drain wire
2 pin: Not connected.
3 pin: Thermistor
4 pin: Thermistor
(4) Crimp the THERMISTOR connector with pliers.
Make sure the crimp is horizontal.
IB-1501268-K
Tube for protection
Cable with shield
Twister shield wire
or drain wire
Insert
336
THERMISTOR connector