Mitsubishi Electric M800W Series Connection And Set Up Manual page 557

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
26 Setting the Tool Entry Prohibited Range
Precautions
(1) The function of disabling movement in the prohibited area works while the tool is within the prohibited area of stored
stroke limit IB or IIB.
The function does not disable any movement within the permitted area (including the boundary).
(2) All the axes for which the function disables movement are indicated in the alarm guidance.
(3) If the tool is at the center of the prohibited area, as illustrated below, the distance to the permitted area in the
positive direction is equal to that in the negative direction. In this case the tool can move in both directions. Note that
when the direction that has the shorter distance to the permitted area is uniquely determined as a result of the tool
movement, the function will disable movement in all the directions except for the said direction.
Current position
X
Prohibited area
X axis direction is
uniquely determined
(4) If this function is used together with the stored stroke limit function that does not support this function, the tool may
be allowed to move towards the prohibited area of the combined stored stroke limit function, as illustrated below. To
prevent this, it is recommended to set the ranges of stored stroke limit IB and IIB to be large enough.
Prohibited area
Basic machine
coordinate system
Permitted
area
Point 2
Point 4
(5) As illustrated below, when stored stroke limit IB and IIB are used together, and the tool enters the overlap of the two
prohibited areas, movement of the tool may be disabled. To prevent this, configure settings so that the prohibited
areas of stored stroke limit IB and IIB will not overlap with each other. (If the tool has entered both prohibited areas
due to an incorrect setting, disable stored stroke limit IIB to move the tool.)
Prohibited area IIB
Prohibit-
ed area
IB
Overlap area
of the two
prohibited
areas
Not movable in any direction
IB-1501268-K
Basic machine coordinate system
Y axis can
move in plus
or minus
direction
Move in X(-)
Permitted area
and Y(+)
direction
Y
Point 1
Current position
Point 3
Widen the
prohibited
Prohibited
area IB, IIB
Tool moves to another
prohibited area by mistake
Specify the prohibited
areas of IB and IIB so
that they will not overlap
X
After the movement, the direction with
the shortest distance to the permitted
area is determined, so the other direction
will be disabled.
Prohibited area
Basic machine
coordinate system
Permitted
area
area
Point 2
Point 4
Prohibited area IIB
Prohibited
area IB
Movable
518
Y
Point 1
Current position
Point 3
Prohibited
area IB, IIB
Make the prohibited area of
IB or IIB wider so that the
control will determine the
correct movement direction

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents