Mitsubishi Electric M800W Series Connection And Set Up Manual page 151

Hide thumbs Also See for M800W Series:
Table of Contents

Advertisement

M800W/M80W Series Connection and Setup Manual
4 General Specifications
(9) DCIN (24VDC input)
1
1
I
+24V
2
0V
3
FG
<Cable side connector type>
Connector : 2-178288-3
Contact : 1-175218-5
Manufacturer: TE Connectivity
(a) Specifications of power supply
Consider the following characteristics when selecting the stabilized power supply (prepared by machine
tool builder). Use a power supply that complies with CE Marking or that follows the safety standards given
below.
[Stabilized power supply selection items]
Output
Power capacity
Output holding time
Overcurrent protection
[Standards]
Safety Standards: UL1950, CSA C22.2 No.234 approved, IEC950 compliant
Noise Terminal Voltage: FCC Class A, VCCI-Class A
High Harmonics Current Restrictions: IEC61000-3-2
(Note)
CAUTION
1. Using a stabilized power supply without overcurrent protection may cause the unit's failure due to miswiring of
24V.
(10) KEYUSB (Personal computer unit connection)
(11) NCKB
IB-1501268-K
3
Item
Voltage fluctuation
Ripple noise
24VDC voltage may drop instantaneously due to rush current at the beginning of 24V power
supply to the operation panel I/O unit. The level of voltage drop depends on the capacity of the
power supply. Do not share the power supply with the devices that have alarms to warn the
voltage drop.
Standard setting
±5% or less of 24VDC
200mV (P-P)
Calculate the current value as a reference of maximum current
consumption for the unit which uses the power supply.
20ms
Required
112

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80w seriesM850wM830wM80w

Table of Contents